Search results for "Prosthesis Design"

showing 10 items of 245 documents

In vitro comparison of primary stability of two implant designs in D3 bone

2016

Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…

02 engineering and technologyIn Vitro Techniques03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral DentistryOrthodonticsDental Implantsbusiness.industryResearchSignificant differenceImplant designDental Implantation Endosseous030206 dentistry021001 nanoscience & nanotechnologyImplant stability quotient:CIENCIAS MÉDICAS [UNESCO]Denture RetentionResonance frequency analysisOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgery0210 nano-technologybusiness
researchProduct

Influence of short implants geometry on primary stability.

2018

Background A correct design is needed in short implants to improve primary stability (PS) in low quality bone. This study aimed to compare PS of double thread and single thread short implants. Material and Methods Thirty implants with single thread design (PHI/SHORT-I) and 30 implants with double thread design (PHIA/SHORT-I) (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in 30 randomly selected bovine ribs. PS was assessed in implant stability quotients (ISQ) and periotest values (PV) with Osstell™ and Periotest® devices, respectively. Computed tomographies of the ribs were taken and bone quality was evaluated in Hounsfield Units (HU) using Ez3D Plus software (Vatech Co., Kor…

0206 medical engineeringDentistry02 engineering and technologyBone and BonesDental Prosthesis Retention03 medical and health sciences0302 clinical medicineHounsfield scaleBone qualityMedicineAnimalsGeneral Dentistrybusiness.industryResearchDental Implantation Endosseousfood and beverages030206 dentistry:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringShort implantsOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral Surgerybusiness
researchProduct

Influence of supracrestal tissue attachment thickness on radiographic bone level around dental implants: A systematic review and meta-analysis.

2019

The present systematic review and meta-analysis was carried out to determine the extent to which supracrestal tissue attachment (STA) thickness affects marginal bone loss (MBL) around dental implants. An electronic search was conducted in PubMed (MEDLINE), EMBASE, and complementary sources covering the period up to June 2018. The studies were meta-analyzed based on implant position with respect to the alveolar bone crest (crestal/supracrestal). The MBL values were categorized according to STA width (thick/thin). Of the 1062 eligible titles, nine articles were included in the review. The implants were positioned crestal or supracrestal with respect to the alveolar ridge. The difference betwe…

0301 basic medicineDental Implantsbusiness.industryRadiographyDental Implantation EndosseousAlveolar Bone LossDentistrySoft tissue030206 dentistry03 medical and health sciences030104 developmental biology0302 clinical medicineDental Prosthesis DesignMeta-analysisStatistical significanceAlveolar ridgeAlveolar ProcessPeriodonticsMedicineHumansImplantBone levelbusinessDental alveolusJournal of periodontal researchREFERENCES
researchProduct

Accuracy combining different brands of implants and abutments

2013

Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to- abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands,…

AbutmentDentistryDental AbutmentsOdontologíaProsthesis DesignVertical fitSem micrographsProsthesis fittingDental AbutmentsClinical and Experimental DentistryProsthesis FittingCIENCIA DE LOS MATERIALES E INGENIERIA METALURGICATorqueProsthesis designGeneral DentistryProsthetic abutmentMathematicsDental Implantsbusiness.industryImplant:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludTorqueOtorhinolaryngologyCombinationUNESCO::CIENCIAS MÉDICASDentalResearch-ArticleSurgeryImplantbusiness
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.

2014

Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …

AdultDepth of focusPhakic Intraocular LensesVisual acuityCorneal Wavefront Aberrationgenetic structuresVisual AcuityDiagnostic Techniques OphthalmologicalPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineHumansComputer SimulationAdaptive opticsDioptreMathematicsWavefrontDepth PerceptionPupilPresbyopiaPresbyopiamedicine.diseaseeye diseasesSensory SystemsOphthalmologySpherical aberrationOptometrySurgerysense organsmedicine.symptomJournal of cataract and refractive surgery
researchProduct

KTP-laser stapedotomy with a self-crimping, thermal shape memory Nitinol SMart piston: 1 year follow-up results: how we do it.

2008

AdultMale1 year follow upLasers Solid-StateStapes SurgeryProsthesis Designlaw.inventionPistonOpticsOtoscopesPostoperative ComplicationslawProsthesis FittingThermalAlloysMedicineHumansAgedbusiness.industryAuditory ThresholdShape-memory alloyEquipment DesignMiddle AgedOssicular ProsthesisOtosclerosisOtorhinolaryngologyKtp laserAudiometry Pure-ToneFemalebusinessBone ConductionFollow-Up StudiesClinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-LaryngologyCervico-Facial Surgery
researchProduct

Effect of a distal weight-bearing implant on visual analog scale scores in 23 transfemoral amputees.

2018

The objective of this interrupted time series clinical trial was to evaluate the effect of a distal weight-bearing implant on well-being in patients with transfemoral amputations using the visual analog scale (VAS). A total of 29 patients from five hospitals with previous transfemoral amputations were surgically implanted with an osseoanchored implant with a distal spacer that allows a direct load on the residuum over the distal surface of the socket. Patients were followed for a 14-month period and assessed presurgically and postsurgically using the VAS. The Wilcoxon test was used to evaluate the differences between variables. VAS mean scores improved significantly after intervention. Sign…

AdultMaleAdolescentVisual Analog ScaleVisual analogue scaleDentistryPhysical Therapy Sports Therapy and RehabilitationArtificial Limbsmedicine.disease_causeProsthesis DesignWeight-bearingWeight-Bearing03 medical and health sciencesYoung Adult0302 clinical medicineAmputeesmedicineHumansIn patientVas scoreAged030203 arthritis & rheumatologyAged 80 and overbusiness.industryRehabilitationInterrupted time seriesMiddle AgedFemaleImplantbusiness030217 neurology & neurosurgeryInternational journal of rehabilitation research. Internationale Zeitschrift fur Rehabilitationsforschung. Revue internationale de recherches de readaptation
researchProduct

Biomechanical implications of excessive endograft protrusion into the aortic arch after thoracic endovascular repair

2015

Endografts placed in the aorta for thoracic endovascular aortic repair (TEVAR) may determine malappositioning to the lesser curvature of the aortic wall, thus resulting in a devastating complication known as endograft collapse. This premature device failure commonly occurs in young individuals after TEVAR for traumatic aortic injuries as a result of applications outside the physical conditions for which the endograft was designed. In this study, an experimentally-calibrated fluid-structure interaction (FSI) model was developed to assess the hemodynamic and stress/strain distributions acting on the excessive protrusion extension (PE) of endografts deployed in four young patients underwent TE…

AdultMaleAortic archmedicine.medical_specialtyHemodynamicsAorta ThoracicHealth InformaticsProsthesis DesignBlood Vessel Prosthesis ImplantationYoung AdultAortic aneurysmBlood vessel prosthesismedicine.arteryInternal medicineFluid-structure interactionStentHumansMedicineThoracic aortaStent-graftHemodynamicEndovascular ProcedureAortaAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresHemodynamicsmedicine.diseaseCurvatures of the stomachBlood Vessel ProsthesisComputer Science ApplicationsSurgeryAlgorithmRadiographyDescending aortaCalibrationCardiologyEndograft collapse/infoldingStentsStress MechanicalThoracic endovascular aortic repair (TEVAR)businessAlgorithmsBird-beakHumanComputers in Biology and Medicine
researchProduct

The anatomy of the proximal radius: implications on fracture implant design.

2012

Background The proximal radius features a complex anatomy. Several studies have been published on the anatomy using different technical approaches; however, most of these studies were conducted with a special focus on parameters relevant to radial prosthetic design. The purpose of our study was to explore the complex geometry of the proximal radius with regard to fracture implant design. Methods Our computed tomography-based measurements of 78 multiplanar reformatted radii allow for exact assessment of its geometry and offer a scientific rationale towards the design of fracture implants. We conducted measurements on the radial head, the radial neck, the radial tuberosity, the radial head-to…

AdultMaleElbow ProsthesisProsthesis DesignFractures BoneYoung AdultmedicineHumansOrthopedics and Sports MedicineAgedAged 80 and overRadial neckNormal anatomybusiness.industryImplant designRadial headGeneral MedicineRadial tuberosityAnatomyRadiusMiddle AgedRadiusmedicine.anatomical_structureProximal radiusFracture (geology)SurgeryFemalebusinessElbow InjuriesJournal of shoulder and elbow surgery
researchProduct